Microsoft has pushed Windows 10 Mobile/PC Build 14393.1914 (KB4051033) to those on Anniversary update.
You can check the update availability by going to Settings–>Update & Security–>Windows update–>Check for updates. Coming to what is there in changes/fixes/improvements, there are expectedly no significant changes. But there are lots of fixes and improvements.
You can check the full changelog of Windows 10 Mobile/PC Build 14393.1914 (KB4051033) below.
Windows 10 Build 14393.1914 (KB4051033) Changelog:
Improvements and fixes
This update includes quality improvements. No new operating system features are being introduced in this update. Key changes include:
- Addressed issue where screen tearing and scrambled content appear in applications when a computer is connected to three or more USB 3.0 display devices. This occurs when you change the content on one or more of the connected display devices.
- Addressed issue where a service fails to start when two or more services are using the same built-in account (such as NetworkService or LocalService). When this issue occurs, the failing service reports the error, “The service did not start due to a logon failure”, or, “A specified logon session does not exist. It may already have been terminated.”
- Addressed issue where scheduled tasks with stored credentials fail to run when Credential Guard is enabled. The task fails and reports event ID 104 with the following message: “Task Scheduler failed to log on ‘\Test’ . Failure occurred in ‘LogonUserExEx’ . User Action: Ensure the credentials for the task are correctly specified. Additional Data: Error Value: 2147943726. 2147943726 : ERROR_LOGON_FAILURE (The user name or password is incorrect).”
- Addressed issue where, during BitLocker decryption or encryption of a drive, files protected with the Encrypting File System (EFS) may become corrupted.
- Addressed issue where opening Microsoft Office files from a file server that has Windows Information Protection enabled fails with the error, “Sorry we couldn’t open document xxxx”.
- Addressed issue where a Storage Spaces Direct (S2D) drive that is failing or being removed from a node is incorrectly reported as healthy in admin tools. These tools include Get-Physical Disk, Server Manager, and Failover Cluster Manager.
- Addressed issue where a repair job could be suspended indefinitely after re-adding a node to an S2D cluster.
- Addressed issue where an incomplete Storage Spaces repair could lead to faulty metadata causing future repairs to stop working.
- Addressed issue in the Network Flyout where closing the sign-in dialog unexpectedly (e.g., clicking outside the window) prevents additional sign-in dialogs from appearing when the user tries to connect to the same network.
- Addressed a token leak in services.exe that occurs after applying MS16-111/KB3175027. This results in a kernel session object leak that degrades system performance over time. This especially affects Terminal Server implementations, where more user logons typically occur.
- Addressed an AppProxy issue that could prevent mobile devices from connecting to a network.
- Addressed issue where the Remote Desktop clipboard redirection policy doesn’t take effect if reconnecting to an existing session and the policy has changed between the initial connection and reconnecting to the session.
- Addressed issue where in a non-English language environment, the OEM OOBE process cannot finish when building a failover cluster. This process fails with the error message, “No integration component with the given name could be found.”
- Improved performance when querying the file system formats of Direct-Access Storage Devices.
- Addressed issue associated with the clustering health policy for handling unresponsive clustered drives. By default, drives are retired for unresponsive conditions. The frequency of unresponsive reset remediation is too aggressive.
- Addressed issue in the Network Flyout where closing the sign-in dialog unexpectedly (e.g., clicking outside the window) prevents further sign-in dialogs from appearing when the user tries to connect to the same network.
- Improved performance when launching applications that use Virtual Disk Service to manage volumes.
- Addressed issue that impacted some Epson SIDM (Dot Matrix) and TM (POS) printers, which were failing to print on x86 and x64-based systems. This issue affects KB4048953.
If you installed earlier updates, only the new fixes contained in this package will be downloaded and installed on your device.
Windows Update Client Improvement
Microsoft will release an update directly to the Windows Update Client to improve Windows Update reliability. It will only be offered to devices that haven’t installed the most recent updates.
Known issues in this update
After installing this KB, Internet Explorer 11 users who use SQL Server Reporting Services (SSRS) may not be able to scroll through a drop-down menu using the scroll bar. | Utilizing the scroll wheel on a mouse works as expected. This issue only applies to document mode 11, so attempting to load the page with document mode 10 may work around the issue. To change the document mode in Internet Explorer 11:
Microsoft is working on a resolution and will provide an update in an upcoming release. |
After installing KB4041688, KB4052231, or KB4048953, the error “CDPUserSvc_XXXX has stopped working” appears. Additionally, Event ID 1000 is logged in the Application event log. It notes that svchost.exe_CDPUserSvc_XXXX has stopped working and the faulting module name is “cdp.dll”. | Microsoft is working on a resolution and will provide an update in an upcoming release. Until then, follow the steps in the Per-user services in Windows 10 and Windows Server article. |